PT500-806 LCD differential pressure transmitter
The minimum pressure difference is 100Pa;
3-5 times withstand voltage, suitable for dry gas differential pressure / gauge pressure measurement;
High precision, stable, digital calibration adjustment, amplifier integrated circuit;
Five digit LCD display meter, adjustable decimal digits; Header sampling rate: 20 times/s, percentage display bar
Zero, full, temperature compensation, linear compensation;
Aluminum alloy oxidation shell; 8mm + m10quick plug process connection;

Common keywords:
Digital differential pressure transmitter digital differential pressure sensor
Digital differential pressure transducer
Micro differential pressure transducer
Product description of strain type pressure transmitter:

Model: PT500-806


The minimum pressure difference is 100Pa;
3-5 times withstand voltage, suitable for dry gas differential pressure / gauge pressure measurement;
High precision, stable, digital calibration adjustment, amplifier integrated circuit;
Five digit LCD display meter, adjustable decimal digits; Header sampling rate: 20 times/s, percentage display bar
Zero, full, temperature compensation, linear compensation;
Aluminum alloy oxidation shell; 8mm + m10quick plug process connection;

Common keywords:
Digital differential pressure transmitter digital differential pressure sensor
Digital differential pressure transducer
Micro differential pressure transducer


Chip:
The minimum pressure difference is 100Pa;
3-5 times withstand voltage, suitable for dry gas differential pressure measurement;
Zero, full, temperature compensation, linear compensation;
High impedance, high precision and high stability;
More than 1 million times of service life;

Signal processing and output:
24 bit ADC sampling and processing chip;
DSP digital signal conditioning algorithm;
Multipoint line temperature calibration;
Voltage and current overload protection;
Standard industrial signal output: 4-20mA (two wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);
Five digit LCD display meter, adjustable decimal digits; Header sampling rate: 20 times/s, percentage display bar

Digital communication signal output: rs485-rtu
Advanced 32bit microprocessor and 24bit ADC are adopted
The general MODBUS-RTU protocol is used as the transmission protocol
Baud rate: 1200 ~ 57600bps, check bits: none, odd, even
Support the user's secondary calibration, reset, anti reset, restore factory and other operations
Support 11 kinds of unit switching, support floating-point, integer, percentage, formatted output

Structure:
Aluminum alloy oxidation shell; 8mm + m10quick plug process connection;
The structure is small, the tightening nut is waterproof, and the outlet is electrically connected;
Supporting four / five core shielded cable;

Application:
Pressure measurement and monitoring of furnace negative pressure, dust-free workshop, Department, etc;
Pressure measurement and monitoring of front and back end of filter net, building, ventilation, etc;
Pressure measurement and monitoring of dust collection pipeline, waste gas treatment, etc;



Application fields:
  • Smart city

  • Fire fighting system

  • Natural gas pipeline

  • Air supply system

Specification parameter

PT500-806


Measuring medium: dry gas

Pressure type: differential pressure

Range:
0~100、200、300、500、1000(Pa);
0~1、2、3、5、10、20、30、40、50、70、100(KPa);
-100KPa~-10KPa~0~100(KPa);
±500Pa~±100KPa;

Static pressure: 3-5 times of the range
Comprehensive accuracy: ± 0.25% FS;±0.5%FS;±1%FS
Nonlinear: ≤ 0.5% FS
Repeatability: ≤ 0.25% FS

Output signal:
Current mode: 4 ~ 20mA two wire system;
Voltage type: 0 ~ 5VDC, 0 ~ 10VDC three wire system
Digital type: rs485-rtu; Rs485-rtu/low power consumption
Hybrid: rs485-rtu + 4 ~ 20mA
Temperature pressure integration: rs485-rtu + Pt100
Low power integrated temperature and pressure: rs485-rtu + Pt100
Five digit display, adjustable decimal point, sampling rate: 20times/s

Power supply voltage: 24 VDC (9-30 VDC)/low power output power supply voltage: 3.6VDC (3.1-5VDC)
Service life: ≥ 1 million times
Insulation impedance: ≥ 1000 m Ω/100VDC
Load impedance: current output: ≤ 800Ω; Voltage output: ≥ 50KΩ
Medium temperature: - 20 ~ 70 ℃/
Ambient temperature: - 20 ~ 70 ℃
Compensation temperature: 0 ~ 60 ℃
Response time: ≤ 3MS
Overload pressure: 150%FS
Failure pressure: 3 times of the measuring range (the measuring range is less than 40MPa); 2 times of measuring range (measuring range greater than 41mpa)
Electrical connection: Waterproof tight wire nut direct outlet, supporting explosion-proof electrical connection
Protection grade: IP65/IP68
Connecting cable: tightening nut, standard length: 3M
Connection material: aluminum alloy
Process connection: φ 8 quick plug + m10thread (general)... User can make specification

Ordering considerations
Precautions for use
Common problem
Proposal
Name
Tel
QQ
WeChat
Mailbox
Address
Content
Foshan puliang Electronic Co., Ltd

Tel:0757-26619568 Fax: 0757-26619508

24-hour online technical support:13790092618

Cloud platform:www.puliangiot.com

Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

Copyright©Foshan puliang Electronic Co., Ltd